NTSB Identification: NYC75AN013
14 CFR Part 91 General Aviation
Aircraft: AMER AVCO AA1-B, registration: N9630L
----------------------------------------------------------------------------------------------------------------------------
 FILE    DATE          LOCATION          AIRCRAFT DATA       INJURIES       FLIGHT                        PILOT DATA
                                                               F  S M/N     PURPOSE
----------------------------------------------------------------------------------------------------------------------------
3-2337  74/7/28    HOLBROOK,NY         AMER AVCO AA1-B     CR-  2  0  0  INSTRUCTIONAL             COMMERCIAL, FL.INSTR.,
        TIME - 1510                    N9630L              PX-  0  0  0  DUAL                      AGE 42, 1207 TOTAL HOURS,
                                       DAMAGE-DESTROYED    OT-  0  0  0                            400 IN TYPE, INSTRUMENT
                                                                                                   RATED.
        NAME OF AIRPORT - ISLIP-MACARTHUR
        DEPARTURE POINT             INTENDED DESTINATION
          HOLBROOK,NY                 LOCAL
        TYPE OF ACCIDENT                                         PHASE OF OPERATION
           ENGINE FAILURE OR MALFUNCTION                            TAKEOFF: INITIAL CLIMB
           STALL                                                    TAKEOFF: INITIAL CLIMB
        PROBABLE CAUSE(S)
           PILOT IN COMMAND - MISMANAGEMENT OF FUEL
           MISCELLANEOUS ACTS,CONDITIONS - INATTENTIVE TO FUEL SUPPLY
           MISCELLANEOUS ACTS,CONDITIONS - FUEL STARVATION
           PILOT IN COMMAND - FAILED TO OBTAIN/MAINTAIN FLYING SPEED
        FACTOR(S)
           TERRAIN - HIGH OBSTRUCTIONS
           MISCELLANEOUS ACTS,CONDITIONS - TOUCH AND GO LANDING
        COMPLETE POWER LOSS - COMPLETE ENGINE FAILURE/FLAMEOUT-1 ENGINE
        EMERGENCY CIRCUMSTANCES - FORCED LANDING ON AIRPORT/SEAPLANE BASE/HELIPT.
        REMARKS- SELECTOR L,FUEL TANK-EMPTY. R FUEL TANK 9.5GAL. OWNRS MAN-RCMD CHNG TANKS EVERY 30MIN.
Full narrative is not available


​​​​​​