NTSB Identification: OAK75FVG62
14 CFR Part 91 General Aviation
Aircraft: PIPER PA-18A, registration: N9799D
----------------------------------------------------------------------------------------------------------------------------
 FILE    DATE          LOCATION          AIRCRAFT DATA       INJURIES       FLIGHT                        PILOT DATA
                                                               F  S M/N     PURPOSE
----------------------------------------------------------------------------------------------------------------------------
3-1128  75/5/10    HOOD,CA             PIPER PA-18A        CR-  1  0  0  COMMERCIAL                COMMERCIAL, AGE 50, 7000
        TIME - 0815                    N9799D              PX-  0  0  0  AERIAL APPLICATION        TOTAL HOURS, 4000 IN
                                       DAMAGE-DESTROYED    OT-  0  0  0                            TYPE, NOT INSTRUMENT
                                                                                                   RATED.
        NAME OF AIRPORT - JOHNSON STRIP
        DEPARTURE POINT             INTENDED DESTINATION
          HOOD,CA                     LOCAL
        TYPE OF ACCIDENT                                         PHASE OF OPERATION
           STALL: SPIN                                              IN FLIGHT: PULLUP FROM SWATH RUN
        PROBABLE CAUSE(S)
           PILOT IN COMMAND - FAILED TO OBTAIN/MAINTAIN FLYING SPEED
         SPECIAL DATA
          TOTAL HOURS IN CROP CONTROL - 4000                       KIND OF OPERATION - SPRAYING CROPS
          KIND OF CROP - GRAIN FIELDS                              TYPE OF CHEMICAL USED - LIQUID CHEMICAL-TOXIC
          PILOT' S SEAT BELT -FASTENED-PROPERLY                    GLOVES - NOT USED
          GOGGLES - NOT USED                                       CRASH HELMET - AVAILABLE-NOT USED
          COCKPIT CRASHPAD - NOT INSTALLED                         CRASH BAR - NOT INSTALLED
          TANK/HOPPER-LOCATION - AFT OF PILOT                      TERRAIN-TYPE -LEVEL,FLAT
          ELEVATION-AREA BEING TREATED-FEET -  10                  SWATH RUN-HOW FLOWN - CROSSWIND
          PROCEDURE TURNAROUND - ENTRY TO PROCEDURE TURN
Full narrative is not available


​​​​​​