NTSB Identification: OAK67F0130
14 CFR Part 91 General Aviation
Aircraft: WEATHERLY C63, registration: N58541
----------------------------------------------------------------------------------------------------------------------------
 FILE    DATE          LOCATION          AIRCRAFT DATA       INJURIES       FLIGHT                        PILOT DATA
                                                               F  S M/N     PURPOSE
----------------------------------------------------------------------------------------------------------------------------
2-0665  66/8/21    VERNALIS CALIF      WEATHERLY C63       CR-  0  1  0  COMMERCIAL                COMMERCIAL, AGE 31, 2113
        TIME - 0930                    N58541              PX-  0  0  0  AERIAL APPLICATION        TOTAL HOURS, 1500 IN
                                       DAMAGE-DESTROYED    OT-  0  0  0                            TYPE, NOT INSTRUMENT
                                                                                                   RATED.
        TYPE OF ACCIDENT                                         PHASE OF OPERATION
           COLLIDED WITH: OBJECT                                    IN FLIGHT: PROCEDURE TURNAROUND
        PROBABLE CAUSE(S)
           PILOT IN COMMAND - MISJUDGED ALTITUDE AND CLEARANCE
         SPECIAL DATA
          TOTAL HOURS IN CROP CONTROL - UNKNOWN/NOT REPORTED       KIND OF OPERATION - SPRAYING CROPS
          KIND OF CROP - PASTURE                                   TYPE OF CHEMICAL USED - LIQUID CHEMICAL-TOXIC
          PILOT' S SEAT BELT -FASTENED-PROPERLY                    GLOVES - NOT USED
          GOGGLES - USED                                           CRASH HELMET - AVAILABLE USED
          COCKPIT CRASHPAD - INSTALLED                             CRASH BAR - INSTALLED
          TANK/HOPPER-LOCATION - FORWARD OF PILOT                  TERRAIN-TYPE -LEVEL,FLAT
          ELEVATION-AREA BEING TREATED-FEET -  33                  SWATH RUN-HOW FLOWN - CROSSWIND
          PROCEDURE TURNAROUND - ENTRY TO PROCEDURE TURN
        REMARKS- ACFT STRUCK WATER STANDPIPE. PLT HAS NO MEMORY OF FLT.PLTS RESPIRATOR FILTER CHANGE 35 HRS OVERDUE
Full narrative is not available


​​​​​​