NTSB Identification: CHI72AC081
14 CFR Part 91 General Aviation
Aircraft: MITSUBISHI MU-2B, registration: N8400E

----------------------------------------------------------------------------------------------------------------------------
 FILE    DATE          LOCATION          AIRCRAFT DATA       INJURIES       FLIGHT                        PILOT DATA
                                                               F  S M/N     PURPOSE
----------------------------------------------------------------------------------------------------------------------------
3-2820  72/4/11    MILLERSBURG,OHIO    MITSUBISHI MU-2B    CR-  0  0  2  NONCOMMERCIAL             COMMERCIAL, FL.INSTR.,
        TIME - 1635                    N8400E              PX-  0  0  4  CORP/EXEC                 AGE 27, 5400 TOTAL HOURS,
                                       DAMAGE-SUBSTANTIAL  OT-  0  0  0                            1100 IN TYPE, INSTRUMENT
                                                                                                   RATED.
        DEPARTURE POINT             INTENDED DESTINATION
          AKRON,OHIO                  ST.LOUIS,MO
        TYPE OF ACCIDENT                                         PHASE OF OPERATION
           FIRE OR EXPLOSION: IN FLIGHT                             IN FLIGHT: NORMAL CRUISE
           WHEELS-UP                                                LANDING: LEVEL OFF/TOUCHDOWN
        PROBABLE CAUSE(S)
           SYSTEMS - ELECTRICAL SYSTEM: RELAYS AND WIRING
           MISCELLANEOUS ACTS,CONDITIONS - OVERHEATED
           MISCELLANEOUS ACTS,CONDITIONS - EXCESSIVE VOLTAGE
           SYSTEMS - ELECTRICAL SYSTEM: PROTECTIVE DEVICES
           MISCELLANEOUS ACTS,CONDITIONS - MATERIAL FAILURE
        FACTOR(S)
           MISCELLANEOUS ACTS,CONDITIONS - ELECTRICAL FAILURE
           MISCELLANEOUS ACTS,CONDITIONS - FIRE IN CABIN,COCKPIT,BAGGAGE COMPARTMENT
        EMERGENCY CIRCUMSTANCES - FORCED LANDING ON AIRPORT/SEAPLANE BASE/HELIPT.
        REMARKS- SERIES RELAY OVERHEATED ACROSS CONTACTS. 275 AMP CURRENT LIMITER MALFUNCTIONED.LDG GR PARTLY DWN.

Index for Apr1972 | Index of months